Cone Meters

v2.0 help

Mass or gross volume flowrate calculation for cone type meters

This is essentially the ISO 5167 standard modified for the geometry and characteristics of a cone meter.



Configuration


OptionSetting
Fluid Type
Primary Flowrate
Edition
V-Cone Model
Temperature Transmitter Location gallery thumbnail
Temperature Correction Method
Density Location gallery thumbnail
Temperature Exponent Method
Discharge Coefficient
Contains Drain Hole
Energy Flowrate Calculated from

Inputs


FieldUnitsValue
Differential Pressure
Upstream Pressure (p1)
Recovery Point Temperature (t3)
Pipe Diameter
Pipe Coefficient of Expansion
Pipe Calibration Temperature
Device Diameter
Device Coefficient of Expansion
Device Calibration Temperature
Upstream Density
Isentropic Exponent
Fluid Viscosity
Standard Density
Superior Real Volume Based CV
Discharge Coefficient

Intermediates


Field NameValue
Iterations0

Results


DescriptionUnitsActual
Temperature Exponent
Beta Ratio
Temperature Corrected Pipe Diameter
Temperature Corrected Device Diameter
Beta Ratio (Corrected)
Adiabatic Expansion Factor
Thermal Expansion Factor
Flow Coefficient
Permanent Pressure Loss
Downstream Pressure (p2)
Recovered Pressure (p3)
Upstream Temperature (t1)
Downstream Temperature (t2)
Mass Flowrate
Gross Volume Flowrate
Standard Volume Flowrate
Energy Flowrate



PROJECT CODE:
STREAM ID:
TEST NUMBER:
TEST CONDUCTED BY:
TEST WITNESSED BY:
COMMENTS:
TEST DATE:21/08/2017 16:43:43